How to Select the Right Air-Cooled Condensing Unit
How to Select the Right Air-Cooled Condensing Unit
In current times, with the increase in awareness among people, sustainability and energy efficiency have become a staple. Hence, air-cooled condensing units (ACCU) are an essential component in various industrial operations, from chemical manufacturing to food processing or pharmaceuticals. Therefore, making an informed choice to select the best air cooled condensing unit that perfectly aligns with your industrial application is vital.
Goto Kendall to know more.
Let's discover the key factors to consider when selecting an air-cooled condenser to ensure optimal performance and longevity.
Fan Technology
The type of fan utilized in the air-cooled condensing unit significantly impacts its noise levels and energy efficiency. Therefore, advanced fan technologies, including blade design innovations and variable speed fans, optimize and optimize airflows and reduce energy consumption. Noise levels are also a crucial consideration, especially in residential or noise-sensitive environments.
Thermal Efficiency
The air-cooled condensing unit should have the capacity to effectively dissipate heat from the system to maintain optimal operating temperatures. Factors like fin density, tube materials, and overall design greatly influence thermal efficiency. Higher fin density and advanced materials can enhance heat transfer capabilities, ensuring efficient cooling even in challenging conditions.
Environmental Considerations
When you invest in an air-cooled condensing unit from an air-cooled heat exchanger manufacturer, be sure to consider factors like ambient temperature, humidity, and the presence of pollutants that can impact the condensers efficiency. It is crucial to choose a condenser that is designed to withstand the specific environmental challenges of your facility.
Maintenance and Accessibility
It is essential to maintain the air-cooled condensers for performance and longevity regularly. Choose a condenser from Thermosag, a reputed air-cooled steam condenser manufacturer in India, to get a design that facilitates easy access to components for inspection, cleaning, and repairs.
Additional Considerations
Use redundant ACCUs to ensure continuous operation for critical applications. Also, check that the air-cooled condensing unit has advanced control and monitoring systems as they optimize energy efficiency and performance. Adhere to local building codes and regulations regarding ACCU installation and operation.
Conclusion
Choosing a suitable air-cooled condenser requires a comprehensive understanding of your applications requirements and the environmental conditions in which the condenser will operate. Thermosag is one of the reputed air-cooled heat exchange manufacturers in India. Our air-cooled condensers for power plants are robust, efficient, well-equipped, and completely tailor-made. Contact Thermosag to find the best condenser for your project.
How to Choose the Correct Air-Cooled Condenser Based ...
NEWS - April 5
How to Choose the Correct Air-Cooled Condenser Based on THR
-04-01 05:32:57
Proper calculations will ensure refrigeration system operates efficiently
When choosing refrigeration equipment for a new installation, equipment is selected to provide the required refrigeration effect to either reduce and/or maintain a products temperature. This capacity is normally stated in Btuh. The unit cooler (evaporator), compressor, and metering device are all selected based on this Btuh requirement for the selected refrigerant. The only major component not selected based on this Btuh requirement is the condenser.
A condenser must be selected for the systems total of heat rejection (THR), which is the sum of the heat energy absorbed by the evaporator and the additional heat energy added to the refrigerant by the compressor. This additional heat energy is referred to as the heat of compression. The heat of compression varies with the compressor design, so the compressor manufacturers information should be used whenever possible. If this information is not available, many condenser manufacturers will provide a reference table to determine that value.
Selecting an air-cooled condenser is not always necessary; many times, a condensing unit is selected for the installation. The condensing unit is selected based on the required Btuh capacity, and its condenser is selected by the condensing unit manufacturer. However, systems using a remote air-cooled condenser will need to have the condenser chosen separately.
To begin the selection process, first determine the systems THR by adding in the compressors heat of compression (obtained from either the compressor manufacturer or a table from the condenser manufacturer). If the condenser will be installed above sea level, a correction factor will need to be applied to the THR. The condenser manufacturer will generally have a table available providing the required correction factors.
Want more information on air cooled condensing units exporter? Feel free to contact us.
Next, calculate the design temperature difference (TD), which is the design condensing temperature minus the design ambient temperature:
Design TD = Condensing temperature - Ambient temperature
Next, for the systems refrigerant type, use the manufacturers selection chart to choose the condenser based on the THR and look at the design temperature difference. Some manufacturers charts may show their condensers capacity at a 1°F temperature difference. If necessary, you can determine the required TD at 1°F by dividing the THR by the design condenser TD:
THR/°TD = THR ÷ Calculated design condenser TD
If the required THR falls between two condenser capacities on the selection chart, chose the higher of the two. For example, lets say you are selecting a remote air-cooled condenser for a system with a net refrigeration requirement of 225,000 Btuh.
The condenser will be installed at sea level, so no factor for altitude correction is required. It is a low temperature system utilizing a R-404A semi-hermetic, suction cooled compressor with a design evaporating temperature of -20°F, an outdoor ambient of 90°F, and design condensing temperature of 110°F. According to the condenser manufacturers Heat of Compression Factor for Suction Cooled Compressors table, a multiplication factor of 1.55 should be used to determine the THR. Using this factor, the THR will be 348,750 Btuh (225,000 Btuh x 1.55). The design condenser TD will be 20°F (110°F - 90°F). Referencing the condenser manufacturers selection table for their R-404A condensers, it is possible to select the correct air-cooled condenser for the installation.
Selecting the correct air-cooled condenser for an installation is a vital part of ensuring the system operates properly and at peak efficiency.
AUTHOR NOTES
JOE MARCHESE
Author, instructor, HVACR contractor, and former RSES president
Contact him at .
©NEWS. View All Articles.
How to Choose the Correct Air-Cooled Condenser Based on THR
https://digital.bnpmedia.com/article/How+to+Choose+the+Correct+Air-Cooled+Condenser+Based+on+THR///article.html
The company is the world’s best air cooled condensing units manufacturer supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
- Previous: None
- Next: Understanding AC Condensing Units in Facilities Management